1. Home
  2. Diamonds
  3. Steel design
  4. How do I determine if the structure is sway or non-sway?

How do I determine if the structure is sway or non-sway?

To determine if a structure is sway or non-sway, you can calculate the global buckling factor \alpha_{cr}.

  • Click on  .Choose for a 2nd order calculation. Hit ‘OK’.
    The global buckling factor is determined during a 2nd order analysis.
  • Click on . At the bottom of this window you’ll see the minimum value for the global buckling factor \alpha_{cr} .
    • If \alpha_{cr} 10  → structure is non-sway
    • If \alpha_{cr} < 10  → structure is sway

Was this article helpful?

Related Articles

Need Support?
Can't find the answer you're looking for? Don't worry we're here to help!
CONTACT SUPPORT